Skip to product information
X-Large Faraday Tent – LX Black RF/EMI Shielding Enclosure Room (9′ x 9′ x 6.5′) BERRY COMPLIANT image 0

X-Large Faraday Tent LX Black RF/EMI Shielding Enclosure Room (9'x 9' x 6.5') BERRY COMPLIANT

$47,500.00

Note: 2025 price and availability are subject frequent change due to tariffs and trade uncertainty; all order details will be confirmed with buyer before processing and shipping.

Please note: Due to shipping and customization, a minimum quantity (MOQ) may be required for professional product orders. Please Click the "Questions, Discounts button above for more information". For sample price of 1-10 units, please contact us for a quote.

Pro Documentation: Dimensional Drawings, Dimensions, Performance Graphs, Setup Guides, Support Software, and CAD Models will be provided upon request and by default upon purchase.

Shipping Note: Due to the excessive weight of pro items such as motors and batteries, additional freight charges apply.

Availability: 2025 price and availability may change subject to tariffs and shipping; all orders confirmed with buyer before shipping.

Description:

Product Overview

The X-Large Faraday Tent LX Black RF/EMI Shielding Enclosure Room (9' x 9' x 6.5') Berry Compliant is a portable RF/EMI shielding enclosure designed to comfortably hold multiple individuals in a shielded workspace. It features two shielded honeycomb vents; lower intake with fan and sleeve, upper exhaust, a built-in power strip, extra connectors, tensioning accessories, protective bags, and a rip repair kit. The double-layer construction with Faraday thread and heavy-duty seams ensures durable shielding in demanding environments.

This Large RF shielding room is built to secure an entire area for you to work in a protected room that is free from any outside attempts at manipulating or interfering with your devices. The X-Large tent measures at 526.5 cubic feet. This tent averages -85 dB attenuation in the range of 30 MHz to 1 GHz and an average of -90 dB attenuation in the range of 1 GHz to 11 GHz. Call to custom design a different size tent to better fit your needs. High grade protection. Affordable and Versatile.

Key Technical Advantages

  • Ventilation design: Two shielded honeycomb vents; lower intake with fan and sleeve, upper exhaust.
  • Shielding construction: Double layer, Faraday thread, heavy-duty seams.
  • Operational readiness: Power strip, extra connectors, tensioning accessories, protective bags, rip repair kit.
  • X-Large form factor: X-Large tent — Portable RF/EMI Shielded Enclosures Comfortably holds multiple individuals.
  • Compliance: BERRY COMPLIANT.

Full Specifications

  • Dimensions (L x W x H): (9' x 9' x 6.5')
  • Color / Model: LX Black
  • Compliance: BERRY COMPLIANT
  • Ventilation: Two shielded honeycomb vents; lower intake with fan and sleeve, upper exhaust
  • Construction: Double layer, Faraday thread, heavy-duty seams
  • Contents: Power strip, extra connectors, tensioning accessories, protective bags, rip repair kit

Applications / Use Cases

  • Field and shop floor RF/EMI shielding for personnel and equipment
  • On-site testing, maintenance, and collaborative work in a shielded environment

Temporary shielded workspace for sensitive electronics assembly or evaluation

  • X-Large tent: 9′ x 9′ x 6.5′ (comfortably holds multiple individuals with desks and equipment)
  • Test range: The tent has an average shielding effectiveness of -85 dB attenuation in the range of 30 MHz to 1 GHz and averages -90 dB attenuation in the range of 1 GHz to 11 GHz.
  • Faraday Tents enable maximum, comprehensive security for forensic and anti-espionage investigations. The Faraday Tent secures more than just devices, it secures an entire area so that investigators may operate in a protected field.
  • The 526.5 cubic feet of space within the tent comfortably accommodate multiple operators with plenty of space for desks and equipment. Transmitters are not able to operate from the inside, granting secure communication in anti-espionage investigations. Every tent includes double-wall construction, double mag/zip doors, positive air ventilation, as well as shielded power, Ethernet, and LED lighting.
  • Tents are indispensable in a wide range of forensic situations. Choose from our pre-configured tent packages our customize an enclosure to fit your needs.

Tent allows for easy setup and break down when quick deployment and enclosure is needed. RF/EMI tents offer an affordable alternative to traditional hard wall chambers and soft wall enclosures match shielding effectiveness in comparison. Independent testing of a complete assembled tent system including installed components, resulted in a minimum signal attenuation of -85.7 dB over a range of frequencies from 400 MHz to 18 GHz measuring through the wall at multiple locations. Faraday Defense Tents are offered in standard sizes or you can opt to have an enclosure designed and built to custom specifications

SHIELDING APPLICATIONS

  • EMC Product Compliance Testing
  • RF and EMI Shielding
  • Instrumentation Repair and Calibration
  • Production and Quality Product Line Testing
  • Wireless Service Centers
  • High Voltage Test Labs
  • Secure Computer Rooms
  • Wireless Product Testing
  • Metrology Labs
  • Magnetic Resonance Imaging (MRI)
  • Medical Equipment and Instrumentation
  • Biomedical Engineering Labs
  • Embassies and Consulates
  • TEMPEST Security Areas
  • Forensic Labs
  • NSA 94-106 Applications
  • Drone/UAV (Unmanned Aerial Vehicle) Testing

The following options are available for any of our RF/EMI Shielded Enclosures:

Construction:

  • Flame retardant/resistant liner
  • ESD liner to provide static control
  • Sound reduction/absorbing lining and sound masking systems
  • Exterior covers for outdoor deployment
  • Vestibule entrance
  • Zero-threshold door
  • Custom size door
  • Shielded Windows
  • Detachable floor

Transport:

  • Pelican storage cases
  • Shipping cases
  • Airline compatible travel cases
  • Frame cases

Other:

  • RF / microwave absorbing foam
  • I/O filter plates
  • EMI hardened lights
  • In-house or independent IEEE® 299 (1-18 gHz testing of completed enclosure)
  • Custom engineering/design of enclosure

I/O Plate Filtered Connectors:

  • AC Power
  • DC Power
  • 1G and 10G Ethernet
  • USB: 2.0, 3.0, and C-Speed
  • DB9
  • DB15
  • DB25
  • HDMI 1.4
  • SMA
  • BNC
  • N-Type
  • ST/ST
  • TNC
  • RJ11
  • Custom waveguides

You may also like